SKC002 In Wall No Mixer Showermi$er Installation Guide
Installation Steps
​
-
The Sinkmi$er has four ports (on the back), one inlet and three outlets
-
The inlet port is positioned separately from the other three and is connected from the hot & cold taps or mixer
-
The other three ports are your output ports and are positioned together on the very bottom of the valve
​
The three outputs are as follows (order can be changed)
​
-
The centre port goes straight up to the shower head
-
The right port goes to your return line back to your water tank or inlet (suction) side of water
pressure pump
3. The left port can be capped off or attached to a hand wand, body spray unit, vanity spout, shower
attachment or another water tank
​
​
Magic Mushroom Installation
​
-
The Magic Mushroom (temperature indicator) can be fitted before the hot inlet to the mixer tap, after the mixer tap or to the return line to the water tank
-
Connect to either of the 1/2" sides of the provided clear plastic “T” piece
-
Use 3-5 turns of Teflon tape
-
The 3/4" side of the “T” goes through the wall to the front of the shower where the blue mushroom cap (Provided in the kit) is installed as per the instructions below
-
Screw 3/4" Lock Nut onto 3/4" male thread of the “T”
-
Make sure the flat side is facing out toward end of the threads. Screw it all the way down until it stops
-
Slide rubber washer over 3/4" threads and press against the lock nut
-
Wrap 2 to 3 turns of Teflon tape on the 3/4" end of the “T”
-
Insert “T” into a predrilled 3/8" hole in the shower wall
-
Screw Magic Mushroom onto the 3/4" thread
-
Turn Magic Mushroom until snug then turn slightly more until logo is horizontal. HAND TIGHTEN ONLY
-
Screw 3/4" lock nut until snug against the bottom side of the counter. HAND TIGHTEN ONLY
​
CAUTION when switching lever back to shower, the water will be HOT
​
Make sure you note the position of your Water Tank Gauge sender if you have one
fitted already
​
Our Showermi$er range are not Watermarked / Do not have a WELS Rating
​
Please Note: Due to continuous product improvement, specifications are subject to change without notice
​